• New

HAGER CIRCUIT BREAKER 6A MCB 1P 6kA C-6A 1M

AED25.00
No tax
6A BREAKER
Quantity
Add to wishlist

  Secure payment

By Stripe

  Free Shipping

On orders above AED 200

  Estimated Delivery

Dispatched within 24 hours

Guaranteed safe & secure checkout

       PRODUCT SPECIFICATIONS:

         HAGER CIRCUIT BREAKER 6A MCB 1P 6kA C-6A 1M

 

         TECHNICAL CHARACTERISTICES

 

           Architecture:

  • Neutral Position: Without Neutral
  • Number of Protected Poles: 1
  • Number of Poles: 1P
  • Type of Pole: 1P
  • Curve: C

 

           Functions:

  • Concurrently Switching N-Neutral: No

 

           Configuration:

  • Number of Modules: 1

 

           Connectivity: 

  • Top connection alignment for modular devices: Aligned terminal
  • Bottom connection alignment for modular devices: Aligned terminal

 

           Main Electrical Features: 

  • Rated short circuit breaking capacity Icn AC according IEC60898-1: 6 kA
  • Rated operational voltage Ue: 240 / 415 V
  • Type of supply voltage: AC
  • Frequency: 50/60Hz

 

           Voltage: 

  • Rated insulation voltage: 500V
  • Rated impulse withstand voltage: 4000V

 

           Electric Current: 

  • Rated Current: 6A
  • Rated service breaking capacity Ics AC according to IEC 60898-1: 6 kA
  • min/maxi threshold value of the AC thermal operation: 1.13 / 1.45 In
  • Magnetic regulating current: 5 / 10 In
  • Rated short circuit breaking capacity Icn under 230V AC according IEC60898-1: 6 kA

 

           Electric Current / Temperature:

  • Rating current -25°C: 7.8A
  • Rating current -20°C: 7.7A
  • Rating current -15°C: 7.5A
  • Rating current -10°C: 7.4A
  • Rating current -5°C: 7.2A
  • Rating current 0°C: 7.1A
  • Rating current 5°C: 6.9A
  • Rating current 10°C: 6.7A
  • Rating current 15°C: 6.6A
  • Rating current 20°C: 6.4A
  • Rating current 25°C: 6.2A
  • Rating current 30°C: 6A
  • Rating current 35°C: 5.8A
  • Rating current 40°C: 5.6A
  • Rating current 45°C: 5.4A
  • Rating current 50°C: 5.2A
  • Rating current 55°C: 5A
  • Rating current 60°C: 4.7A
  • Rating current 65°C: 4.5A
  • Rating current 70°C: 4.2A

 

           Current Correction Factors:

  • Correction factor of rating current for 2 devices placed side-by-side: 1
  • Correction factor of rating current for 3 devices placed side-by-side: 0.8
  • Correction factor of rating current for 4 and 5 devices placed side-by-side: 0.7
  • Correction factor of rating current for 6 devices placed side-by-side: 0.6
  • Correction factor of magnetic tripping with 100 Hz: 1.1
  • Correction factor of magnetic tripping with 200 Hz: 1.2
  • Correction factor of magnetic tripping with 400 Hz: 1.5
  • Correction factor of magnetic tripping with 60 Hz: 1

 

           Dimensions:

  • Depth of installed product: 70mm
  • Height of Installed Product: 84.6mm
  • Width of Installed Product: 17.5mm

 

           Frequency: 

  • Frequency: 50 to 60Hz

 

           Power:

  • Total power loss under IN: 1.31W
  • Power loss per pole at IN: 1.31W

 

           Endurance:

  • Electric endurance in number of cycles: 4000
  • Number of mechanical operations: 20000

 

           Installation, Mounting:

  • Type of top connection for modular devices: with Screw
  • Tightening torque: 2,8Nm
  • Type of top rail clip for modular devices: NA
  • Type of bottom rail clip for modular devices: Plastic
  • Type of Bottom Connection for modular devices: Blconnect
  • Top removability for modular devices: No
  • Bottom removability for modular devices: Yes

 

           Connection:

  • Connection cross-sect. flexible conductor: 1 / 25mm²
  • Connection cross-sect. rigid cable: 1 / 35mm²
  • Connection cross-section of input and output with screws, for massive conductors: 1 / 35 mm²
  • Connection cross section of access and exit with screws, for flexible conductor: 1 / 25 mm²
  • Type of connection: with Screw

 

           Equipment:

  • Quick connect: No
  • With transparent product label holder: Yes

 

           Standards:

  • Standard text: IEC 60898-1
  • European directive WEEE: not concerned

 

         Safety:

  • REACH Conform: No
  • RoHS Conform: Yes
  • Halogen Free No

 

           Use Conditions:

  • Operating temperature: -25…70 °C
  • Degree of pollution according to IEC 60664 / IEC 60947-2: 2
  • Class of energy limitation I²t: 3
  • Altitude: 2000m
  • Air humidity protection: for all Climates
  • Storage/transport temperature: -25…80 °C

 

           Identification:

  • Aesthetic for B.G. Protection devices: PD

 

           Data Sheet of Product MCN106

Hager
6A BREAKER
100 Items

16 other products in the same category:

This website uses cookies to ensure you get the best experience on our website